inspection criteria
Homeinspection criteria
click:Date:2022/7/21
Product Description |
Document No. |
Revision No. |
||||
Carpet gripper |
|
V3 |
||||
Inspection Check List |
||||||
No. |
Defect Type |
Inspection item |
Testing Condition / Acceptable criteria |
Method |
Equipment |
Sampling plan |
1 |
MAJ |
Package appearance |
> No noticeable damage and/or smear on the carton (or display box) which may degrade the product aspect during sales. |
Visual |
N/A |
AQL=1.5 |
2 |
MAJ |
General appearance |
> Type of plywood shall be no discrepancy to Reference Sample; > Dent, chipped mark, or any aesthetic defect on the strip with width over 3/4 inch and length over 2 inch not allowed; (Natural knot on the laminate could be acceptable) > End split or open joint, over 1 inch not allowed; |
Visual & Measuring |
Ruler |
Special SS* AQL=1.5 |
3 |
MAJ |
Print |
> Print color of brand mark no obviously discrepancy to Reference Sample; > major |
Visual |
N/A |
Special SS* AQL=1.5 |
4 |
MAJ |
Strip bending |
> No noticeable spring (side bend) , or upswept at the two end of the strip per visual inspection; > Select 3 trips from the visual inspected samples to measure the maximum bending dimension: maximum bow < 2 inch; maximun spring (side bend) < 1/4 inch; |
Visual & Measuring |
Ruler |
Special SS* AQL=1.5 |
5 |
MAJ |
Anchoring Nail Size |
> There shall be 10 pre-nailed anchoring nails on each strip. The type of nails shall be same as Master Sample. > Submit the suspected samples for dimension measurements with allowed tolerance: ± 5%. |
Visual & Measuring |
Caliper |
Special SS* AQL=1.5 |
6 |
MAJ |
Anchoring Nail Missing |
> Maximum 1 missing nails are allowed on each strip. > Missed nail's position shall not be consecutive and/or on either end of the strip. |
Visual |
N/A |
Special SS* AQL=1.5 |
7 |
MAJ |
Hardness of Nails |
> Install three strips onto concrete flooring, no bending, crack allowed on the nails during hammering。 > Randomly measure 3 Anchoring nails from different strips: HRC ≥ 48. Note: only apply to producs with concrete nails. |
Visual |
Rockwell Hardness Tester |
SS=3 AC=0 |
8 |
MAJ |
Pin Assembly |
> Visual check the direction and layout of Pin's assembly, not discrepancy allowed compared to Reference Sample ; |
Visual & Measuring |
Caliper |
SS=8 AQL=1.5 |
9 |
MAJ |
Moisture |
not exceed 8% - 16%. *Record the moisture readings and pend the lots for further disposition if discrepancy detected. |
measuring |
Wood Moisture Meter |
SS=3 AC=0 |
|
||||||
* Notes for Special Sampling plan: Step 1: Randomly select inspection boxes by item per ANSI/ASQC Z1.4 Special Inspection Levels S-4 or S-3 Step 2.Open all selected carton to draw out enough inspection strips per General Inspection Leveis Level-II AQL 1.5. make sure the inspection samples are in average from each openned cartons. e.g.: In case of total 860 boxes (total 86000 strips) for a item# 24424. Then need to open 20 boxes (Sample Size Code "F" for 860 lot size) at first, and then average draw out 125 pcs (Sample Size Code "K" for 2000 strips in these 20 boxes) for final inspection, Ac=5, Rj=6. |
News
Contact us
- Shandong JiaPeng Wood CO.,Ltd
- +86 18353922693
- +86 18353922693
- Wangfu village, Tanyi town, Fei county, Linyi Shandong China 276000